The DCDB Box and ACDB Box is a junction box used in telecommunication and data networks to connect cables. In solar power systems, an ACDB box is used to link AC electricity from inverters to the power grid.
Gsolsolar is a leading provider of Array Junction Box, DCDB (DC Distribution Box) and ACDB (AC Distribution Box) for solar power plants. In order to ensure the effective transfer of electricity from the solar panels to the grid, these boxes are essential to the overall operation of a solar power plant. The following are some advantages of purchasing DCDB Boxes and ACDB Boxes from Gsolsolar
An Array Junction Box is an electrical enclosure used in solar panel systems to connect multiple solar panels together. It provides a centralized location for wire connections, ensuring proper electrical conductivity and protecting against environmental factors.
In conclusion, buying Array Junction Box, DCDB Box and ACDB Box from Gsolsolar can help your solar power plant in a variety of ways. The boxes adhere to industry standards, are manufactured with high-quality components, are adaptable, simple to install and maintain, economical, and come with first-rate customer service
Size – 180x130x100mm
Size – 230x190x100mm
Material – PC / ABS
Degree of Protection – IP65
Brand Name / Model Code |
ACDB Single Phase 32A |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
SPD 2 Pole 320v/410v Type II – 1 pc |
Miniature Circuit Breaker AC |
AC MCB 2 Pole 32 Amp – 1 pc |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
ACDB Single Phase 40A |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
SPD 2 Pole 320v/410v Type II – 1 pc |
Miniature Circuit Breaker AC |
AC MCB 2 Pole 40 Amp – 1 pc |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
ACDB Single Phase 63A |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
SPD 2 Pole 320v/410v Type II – 1 pc |
Miniature Circuit Breaker AC |
AC MCB 2 Pole 63 Amp – 1 pc |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
ACDB Three Phase 32A |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
SPD 4 Pole 320v/410v Type II – 1 pc |
Miniature Circuit Breaker AC |
AC MCB 4 Pole 32 Amp – 1 pc |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
ACDB Three Phase 40A |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
SPD 4 Pole 320v/410v Type II – 1 pc |
Miniature Circuit Breaker AC |
AC MCB 4 Pole 40 Amp – 1 pc |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
ACDB Three Phase 63A |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
SPD 4 Pole 320v/410v Type II – 1 pc |
Miniature Circuit Breaker AC |
AC MCB 4 Pole 63 Amp – 1 pc |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 1 in 1 out 600v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 2 Pole 600v Type II – 1 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 1 in 1 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 1 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 2 in 2 out 600v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 2 Pole 600v Type II – 1 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 2 in 2 out 600v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 2 Pole 600v Type II – 2 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 2 in 2 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 1 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 2 in 2 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 2 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 3 in 3 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 1 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 3 in 3 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 2 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 3 in 3 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 3 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 4 in 4 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 1 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 4 in 4 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 2 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 5 in 5 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 1 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |
Brand Name / Model Code |
DCDB 6 in 6 out 1000v |
Enclosure |
PC / ABS IP67 Wall Mount |
Surge Protection Device |
DC SPD 3 Pole 1000v Type II – 1 pc |
Fuse DC With Holder |
15Amp / 30Amp 1000v DC |
Miniature Circuit Breaker DC |
DC MCB 2 Pole (If Required) |
Cable Glands |
As Required |
Terminal Block Connectors |
As Required |
Din Rail |
As Required |
Input / Output Marking |
Yes |
Earthing Marking |
Yes |